"This e-book offers instruments and suggestions to layout, fee, and function lively and passive beam platforms to accomplish a decided indoor weather. It additionally offers examples of energetic and passive beam calculations and selections"--

summary: "This ebook presents instruments and counsel to layout, fee, and function lively and passive beam structures to accomplish a made up our minds indoor weather. It additionally provides examples of lively and passive beam calculations and choices"

Show description

Read Online or Download Active and passive beam application design guide PDF

Best ventilation & air conditioning books

Ashrae Handbook - 1997 Fundamentals

The industry's such a lot finished resource of HVAC and refrigeration details for greater than 60 years. each bankruptcy undergoes a rigorous four-year assessment procedure that examines the content material and precludes product or procedure bias.

Geotechnical Earthquake Engineering: Simplified Analyses with Case Studies and Examples (Geotechnical, Geological, and Earthquake Engineering)

. .. "Included at the selection checklist with the exceptional educational Earth Sciences titles 2008" . .. This quantity describes simplified dynamic analyses that bridge the distance among the really restricted provisions of layout codes and the really eclectic equipment utilized in refined analyses. Graphs and spreadsheets are incorporated for the benefit and pace of use of simplified analyses of:soil slope (in)stability and displacements attributable to earthquakes,sand liquefaction and stream because of earthquakes,dynamic soil-foundation interaction,bearing potential and extra cost of shallow foundations,earthquake movement results on tunnels and shafts,frequent liquefaction strength mitigation measures.

Stability Analysis and Design of Structures

Swift advances in analytical equipment and computing let engineers to use stability/stiffness the right way to more and more complicated real-life circumstances. This complex and graduate-level textual content and self-tutorial teaches readers to appreciate and to use analytical layout ideas around the breadth of the engineering sciences.

Dictionary of Building and Civil Engineering: English, German, French, Dutch, Russian

Within the previous few a long time civil engineering has gone through giant technological switch which has, clearly, been refleded within the terminology hired within the undefined. Efforts at the moment are being made in lots of international locations to lead to a systematization and unification of technical terminology mostly, and tbat of civil engineering specifically.

Additional info for Active and passive beam application design guide

Sample text

33 Active and Passive Beam Application Design Guide FIGURE 8-13 Active beams installed perpendicular to façade (façade at top, wall at bottom). 1 is calculated in the following table. 1 ; (Rp x NP + Ra x A) Note the significant difference between the two standards in ventilation airflow requirements. 2 PRIMARY AIRFLOW REQUIRED FOR MOISTURE CONTROL The water vapour addition to the indoor air is generated by the occupants’ metabolisms. The following table (Table 9-1) shows the mass of water vapour generated per unit time and per person based on the degree of activity.

Determine the sensible cooling capacity of the primary air, S,p, Btu/h (kW). 2 × (DBIDA – DBSUP) SI 6. Determine the required sensible cooling capacity from the beam(s), S,b Btu/h (kW), which corresponds to the beam capacity, P, where P is the space-sensible cooling-load-cooling capacity of supply air volume 7. Determine the beam quantity, size, and water flow rate based on the sensible cooling requirement. 8. , as long as the room). In this case, the coil is sized according to the required cooling load.

4 CONDENSATION PREVENTION The implementation of an adequate chilled-water temperature control system, together with the supply of an adequate amount of correctly conditioned primary air, is sufficient to avoid the occurrence of condensation on the beams. Water supply to active and passive beams should not be activated when space dew-point temperatures are above the zone chilled-water supply temperature. It must be ensured that the beam system chilled-water supply is shut off any time the air handler is not in operation and only restored when the space dew-point temperature is safe for noncondensing beam operation.

Download PDF sample

Rated 4.61 of 5 – based on 18 votes